Title:
A Low Impact Alternative to Common Weed Control Systems: the Case of Syngas-Powered Flame Weeding
Author(s):
Morselli, N., Puglia, M., Balboni, C., Ottani, F., Parenti, M., Santunione, G., Pedrazzi, S., Allesina, G., Tartarini, P.
Document(s):
Paper
Poster
Abstract:
In this work, a simple model was created to estimate the benefits of replacing the LPG, currently used in flame weeding, with the syngas generated from a biomass gasification system. Results shown that 60.1 kg ha-1 of agri-pellet are enough to substitute 16.4 kg ha-1 of LPG when a gasification efficiency of 70 % is considered. The model shown a CO2 generation of 49.8 kg ha-1 for each treatment using the LPG device and 94.5 kg ha-1 for the biomass-powered weeder which is, however, a biogenic source of carbon with a neutral impact on the climate. Moreover, for the gasification facility, a 3.3 kg ha-1 co-production of char was considered which led to the possible stock of 9.6 kgCO2 ha-1 each treatment. Eventually, the proposed model suggests that a net saving of 58.5 kgCO2 ha-1 can be realized if LPG flame weeding treatment is replaced with a syngas-powered flame weeder.
Keywords:
biomass, gasification, syngas, flame weeding, vineyards
Topic:
Sustainable Resources for Decarbonising the Economy
Subtopic:
Innovative Biomass Production for Energy Integrated into Traditional Agri-Forestry Systems
Event:
29th European Biomass Conference and Exhibition
Session:
1CV.1.13
Pages:
233 - 236
ISBN:
978-88-89407-21-9
Paper DOI:
10.5071/29thEUBCE2021-1CV.1.13
Price:
FREE